Brand: Mitech Model: MET804 Measuring range: 0-5mm Working time: 10h Main unit weight: 1.5kg Dimensions: 240*175*75mm Package dimensions: 40*30*18cm Total weight: 5kg


Goods are not available in digi afagh warehouse. You can call the number: 3 - 71 90 33 88 - 021

Review

Product Overview
Mitech MET Series Portable Eddy Current Flaw Detector,also known as digital electromagnetic detecor,based on the principle of electromagnetic induction,can detect various metal parts surface or near surface defects with high-speed. It uses advanced DSP digital processing and FPGA technology innovation designed, with 5.7-inch TFT LCD screen, can clearly display the detection data.The product has high sensitivity, stable performance, multi-channel simultaneous detection and intelligent data analysis, can be equipped with intelligent probe, can also be customized probe according to customer needs , with extended magnetic memory, coating thickness, conductivity measurement and other practical Features. It is widely used in all kinds of metal pipe rods, auto parts, bearings, oil casing, oil control rods, ring metal parts in non-destructive testing and scientific research and other areas of higher education research.It is the necessary professional precision testing equipment to improve production efficiency, saving production costs. 

Function & application
l All kinds of metal pipe rod wire high-speed non-destructive testing (according to user needs customized package of non-

destructive testing solutions);

l Quality quality links of bearing, ring, auto parts and other metal parts manufacturing quality control links;

l Colleges and universities learning, scientific research and other fields;

Working Principle
The eddy current detection technique is based on the principle of electromagnetic induction, and the excitation signal is loaded into the probe coil. When the probe is close to the metal surface, the alternating magnetic field around the coil will generate the induced current on the metal surface.For flat metal, the flow of induced current is a coil concentric circular, shaped like a vortex, named as the eddy current.The size, phase and flow pattern of the eddy current are affected by the conductivity of the specimen.The eddy current also produces a magnetic field that in turn causes the impedance of the detection coil to change.So when the conductor surface or near the surface of the defect or the measurement of metal materials change, the intensity and distribution of eddy currents will be affected by changes in the impact,Which in turn causes a change in the detection coil voltage and impedance.Eddy current testing is based on this change, the indirect feedback of the existence of defects within the conductor and the performance of metal materials have changed.

Working Conditions
l Operation Temperature:0℃-+45℃;

l Storage temperature:-20℃-+50℃;

l Relative humidity:≤85%;

l In an environment free from vibration, corrosive medium, strong magnetic field and Severe dust;

Instrument Features
l Widely used in nuclear power, military, petrochemical, metallurgy, university teaching, machinery manufacturing and other 

fields;

l With modular compact design, small size, light weight, easy to carry, the products can be customized according to 

customer needs;

l The detector with 10Hz-10MHz test frequency range, can meet a variety of different metal detection requirements;

l Using 5.7-inch color TFT-LCD liquid crystal display, menu design, easy to operate, intuitive display;

l One-button to achieve a variety of modes of switching, the operation more convenient. It can quickly detect a variety of 

metal surface defects;

l With customizable magnetic memory, coating thickness measurement, conductivity measurement and other functions;

l It has large capacity rechargeable battery, to meet the long-term outdoor work needs, can also be directly connected 

220V power supply;

l Compatible with a variety of types of probes, and flexible custom wear, wear, plane, point, weld, fan and other probes;

l It can achieve multi-channel multi-frequency simultaneous detection and can achieve limited mixing, high detection 

efficiency, high sensitivity;

l Using eddy current impedance plane and time base scan display technology, real-time multi-window display with the same 

window eddy current signal;

l Chinese and English version of a key to switch, automatic, manual amplitude and phase adjustment, the rapid realization 

of digital analog electronic balance;

l Real-time alarm output, a variety of alarm window mode, non-equal amplitude, asymmetric phase alarm area settings;

l Using professional "digital filter", effectively suppress the interference signal to ensure the accuracy and stability of the 

test;

l Can store a large number of various testing procedures and data, with signal acquisition, read, transfer, analysis, 

storage, playback and other full intelligent processing functions can be connected to the printer to print the file output, 

storage management;

l Consistent with ASME、GB/T、YB、EN、JIG、API-5L、API-5CL、MH/T and other relevant domestic and foreign 

standards.

Instrument Maintenance
l Read the manual carefully before using the instrument. Learn the operation steps and attentions; To avoid damage 

or personal safety accidents due to improper operation.

l The instrument for precision measuring instruments, when using,it should be taken lightly to avoid the human factors 

caused by the sharp impact and fall, resulting in equipment damage, Proposed use of protective cover;

l Probe cable is a wearing element, please avoid distorting pressure. When plugging, it is recommended in the shutdown 

state, and is strictly forced to drag, so as not to pull off the damage;

l Key operation, you should not be too much force, and stained with too much oil and muddy water fingers should not 

touch the instrument;

l Sensor is a key component of picking up the signal, precision sensitive, more fragile, special attention to prevent bruises, 

proper use;

l Long time idle, should be charged regularly (about once a month);

l According to the prompts, when the battery capacity is nearly exhausted, it should be charged in time to avoid affecting 

the use.